Installation des déshumidificateurs EPD50 -EPD30 / DH1200-DH800

Professional Grade Dehumidifiers for Home & Business use.  Designed to Work 247 Safely

Click To Enlarge
Click To Enlarge

SIMPLE INSTALLATION FOR THE WHOLE HOME

Click Image to Enlarge
Click Image to Enlarge
CHECK YOUR PRODUCT IS WORKING HERE
SEE an Installation in a UK HOME HERE
Picture by customer who
bought EPD50 in New Jersey

Garages can be a cold space.  Protect cars,  tools and stored items

 

Rule of Thumb Guide All Installed In Similar Fashion

EPD30 / DH800 – 1 Car Garage

EPD50 / DH1200 – 2 Car Garage

EPD150 / DH2500 – 3 Car Garage

See Garage Page Here

“Car Hotel”

Ducting Vapour Upwards aND eXTENDING dUCTS

use under the home in crawl spaces, cellars or basements

DUCTING OPTIONS EPD50 / DH1200

Dehumidifier Installation

This is a 3-Hole dehumidifier meaning that there is one  fan inside.  It is a turbo fan like the other larger units in the range.  Part of the dried process air is turned around, heated and used to purge the internal adsorption wheel of moisture that can be then vented away.

Moisture is "vented away".  No water is produced.  The moist air is vented to the outside or moved to another area that is well ventilated. Most common installation. If the machine is in the room being dried the internal humidistat can be used to regulate humidity.  If ducted and outside the room or house being dried an external humidistat may be needed.

Perfect for crawl space areas or attic areas.  Close openings to the crawl space and the unit will regulate the humidity.  Use ducting to help spread the dry air around the crawl space area.
Recirculating the air to be dried gives a compound effect and gives faster drying.  This system is a "Negative Pressure" system.   Air has to replace the air that has been exhausted.  In a normal home air is actually being replaced  frequently typically 2.5 times per hour. No home is air tight.
The dehumidifier can be hidden from sight.  It can be placed in a cupboard, in a ceiling void or under a floor.  Dry air is taken from the room, dried and then clean, dry filtered air returned.  External humidistat may be needed in that instance.

To read more about garages see here

Perfect for crawl space areas or attic areas.  Close openings to the crawl space and the unit will regulate the humidity.  Use ducting to help spread the dry air around the crawl space area.

Strong Machine Even Used For Commercial Spot Drying

The model is build to a standard that professionals can also use.  The machine is perfect for focus drying.  Wet air is focussed to where the moisture is. Example of "Positive Pressure" or forcing the dry air into areas it is needed
Having the machine in the area being dried and recirculating the air is the most efficient way of drying.  This system is "Negative Pressure. In a small enclosure, covered with plastic sheeting a frame is needed to ensure the tent maintains structure.  Rooms generally are not air tight so in larger rooms air can leak under doors etc

Used on Boats as a "Carry on" or Installed

Perfect for ducting around the boat or for area such as cabin, engine room or forward locker.  Read More

DUCTING OPTIONS EPD30 / DH800

Dehumidifier Installation

This is a 3-Hole dehumidifier meaning that there is one  fan inside.  It is a Axial fan unlike the other larger units in the range.  Axial fans have the advantage of needing less power but have less fan pressure.  Fan pressure is needed to force through ducting.  That is why there is no ducting flange on the outlet of this unit.  Part of the dried process air is turned around, heated and used to purge the internal adsorption wheel of moisture that can be then vented away.

Moisture is "vented away".  No water is produced.  The moist air is vented to the outside or moved to another area that is well ventilated. Most common installation. If the machine is in the room being dried the internal humidistat can be used to regulate humidity.  If ducted and outside the room or house being dried an external humidistat may be needed.

Perfect for crawl space areas or attic areas.  Close openings to the crawl space and the unit will regulate the humidity.  Use ducting to help spread the dry air around the crawl space area.
Recirculating the air to be dried gives a compound effect and gives faster drying.  This system is a "Negative Pressure" system.   Air has to replace the air that has been exhausted.  In a normal home air is actually being replaced  frequently typically 2.5 times per hour. No home is air tight.
The machine can just be put in any room such as a garage.  Here the larger model is shown but in smaller garages it can be sufficient.  Moisture is simply vented away.  To read more about garages see here

Used on Boats as a "Carry on" or Installed

Used in many areas on boats.  En savoir plus

the EPD50 / DH1200 althiough designed for home applications is sometimes used by restoraion professionals for commercial applications

Applications typiques

CARACTÉRISTIQUES PRINCIPALES

déshumidificateurs pour les sous-sols de 1000 pieds carrés

Choisir le bon modèle pour les applications commerciales typiques

 

L'information doit être classée en règle générale. Tenez compte de la température moyenne à laquelle le déshumidificateur fonctionnera.