DH3500 INOX DryFan 45-Liter-Edelstahl-Trockenmittel-Luftentfeuchter

Stainless steel. 220V supply 50 Hz that can be run off a 12V DC-220V AC converters or 110V to 220V transformers, auto power reset in case of power supply interruption. “4-hole” technology commercial desiccant dehumidifier; water removal 45 liters maximum extraction. Operating range from -20°C up 40°C maximum room temperature for continuous drying applications, with 380 m3/hr air volume capacity (400 m3/hr – exhaust / 125m3/hr – regen air flow). Highly efficient, very quiet fan operation and yet low energy consumption in use for large moisture extraction capacity. 58dB Process air in 125mm – Process air out 125mm – Exhaust air 80mm – Regen air 80mm

Luftentfeuchter installieren Luftentfeuchter von Ecor Pro
Luftentfeuchter Download Benutzerhandbuch Luftentfeuchter von Ecor Pro
vergleichen Sie unsere Produkte Luftentfeuchter von Ecor Pro

Neutral Pressure Focus Flood Drying

Seal the drying tent and focus dry air saving time, money and carbon footprint
Neutral Pressure Outside

Positive Pressure Outside

Neutral Pressure Inside

How to set up a drying tent

NO WATER PRODUCED. MOISTURE IS VENTED AWAY. EVEN UPWARDS.

Ideal for Flood Restoration, Sea Vessels & Catering Applications

45-Liter-Trockenmittel-Luftentfeuchter 220V / 50Hz

Entspricht einem 90-Liter-Kompressor-Luftentfeuchter bei 18°C

Freistehend oder installiert

Industrial dehumidifier DH3500 INOX stainless steel construction with tough epoxy paint finish.Very small for its 45 litre capacity. Will dry 24/7 and dry even down to -20°C/-4°F. Can work up to 40°C/104°F.

Stainless Steel Inside & OutTough Enough Even for Hiring or Restoration

Can be carried by one person. Transported easily with the carrying handles.Self regulating energy usage that adapts to air pressure differences using always the right amount of power to dry effectively

4-Loch-Luftentfeuchter

Input process air is dust filtered & dried. Input air can be ducted in & out with a 125mm / 5″ duct. Wet air exhaust is 80mm / 3″ duct. Regen air can also be ducted into the dehumidifier with a 80mm / 3″ duct.

Die Forschung von Ecor Pro zeigt, dass der DH3500 INOX bei der Trocknung von Gebäuden bei niedrigen Temperaturen vier- bis siebenmal schneller sein wird als ein herkömmlicher Kompressor-Luftentfeuchter

Zugehörige Teile

Erklärte Merkmale

Highly Compact – Small 45 litre dehumidifier in the market.

Dust Filter – Simple reticulated dust filter in metal frame. Shakened clean or easily replaced. Prevents dust particles entering the unit and impeding performance.

Easy Repair – Easy to remove cover for maintenance and eventual repair. Quickly gives easy access to replace cord sets or warn parts via qualified person. Prolongs the lifetime of the DH3500 dehumidifier. Cord sets can be replaced in around 20 minutes

Auf vier Füßen - kratzfeste Plastikfüße.

Carrying Handle – Easy to carry by one person. The removable handles also protect the dehumidifier duct flanges if in transit.

Humidistat Connection – There is no integral humidistat but one can be added very simply. A military standard connector is on the front of the unit.To add this use the remote humidistat EPHUM220. This will turn the dehumidifier on an off automatically.

Duct Air-In & Out - Der Luftentfeuchter hat alle Kanäle mit Flanschen versehen, so dass Kanäle mit 125mm / 5″ harten oder flexiblen Kanälen hinzugefügt werden können.

Perfekt für jedes Klima.

Wet Air Exhaust – The DH25XX has one internal fan compared to two in the DH35XX. Both do not produce water. Works in colder temperatures via vented away moisture. Dried with small negative pressure. Moisture is purged from the system by 15% of the process air.

“Four Hole System” – Two inlets and two outlets.

Regen Filter Housing – The Regen filter housing is a recent addition to the DH35XX model. It can be detached if not required. Used for certain applications.

Power Supply – Thus, 220V supply 50Hz

Auto Reset - Sollte es zu einer Unterbrechung der Stromversorgung kommen, arbeitet der DH35XX weiter, sobald die Stromversorgung wieder hergestellt ist. Perfekt an Orten, an denen die Stromversorgung "schmutzig" ist und andere elektronisch gesteuerte Produkte beeinträchtigen kann.

Ganzmetallbau - Ganzmetall-Edelstahl innen und außen. Entwickelt für Langlebigkeit.

4m / 12′ Power Cord – No need to join cables when placed for instance in crawl spaces or lofts in the home for example.

Dehumidifier Installation

 

 

This is a 4-Hole dehumidifier meaning that there are 2 separate fans inside.  One for the Process-Air (Air that needs to be dried) and the Regen Air that is used to purge the wheel of moistures and is then vented away

Drying a water-damaged room has moved on from the days of lighting a fire and opening the doors and windows. The industry no longer leaves a dehumidifier in the middle of the flood-damaged room with a couple of air movers and hopes for the best, not least because it wastes expensive energy and because contractors are increasingly aware of the need to reduce both their carbon footprint and the time it takes to do the job.

Power availability also means more efficient products can be used on the power supply than more power hungry units.

With saving labour and making effective use of expensive assets increasingly important in a competitive market, focused or targeted drying is a good start, but as we move towards a more sustainable, cost-focused industry, it’s not enough.

Using tenting for target drying ensures the dehumidifier only dries the wet parts of the room and avoids drying unaffected areas, a process that can cause secondary damage by sucking too much moisture out of some of the materials in the rest of the room. In short, drying a whole room to remedy a flood in part of it is remarkably inefficient.

Targeted drying uses plastic sheeting to create a sealed chamber, or ‘tent’, around the wet area of the room, saving significant amounts of energy by not drying the 90% of the room that wasn’t wet in the first place - but even that approach is inefficient.

The inefficiency arises when the tent is fed from outside by the dry air from a desiccant (absorption) dehumidifier, the best choice when drying dense materials like brick or block walls.

As air is blown into the tent, the same volume of air must escape. This positive pressure system means that the drying air is taken from the whole room – as well as from outside if the windows are open. That makes the whole room part of the drying regime, with the dehumidifier forced to dry potentially damp air before putting it into the tent. If the air being fed in can’t be controlled, the drying can’t be controlled either.

The answer is to create a negative pressure system by moving the dehumidifier inside the tent, creating a controlled environment.

Let’s talk maths. In our positive system, a normal three port desiccant dehumidifier moving 150 cubic metres (5300 cft) per hour is probably generating   cubic metres (4200 cft) of dry air for drying and using 30 cubic metres (1000 cft) to dry its wheel. In a typical one cubic metre tent (35 cft) , the air is exchanged 120 times per hour, but if the tent is in a room with a total volume of 60 cubic metres (2100 cft), the air in the room outside the tent is recirculated twice, too – to no purpose.

In a negative system, the air in the tent is exchanged only 30 times but is recirculated 120 times per hour, each time becoming drier, significantly increasing the efficiency of the drying regime and reducing energy usage.

Taking this a step further, Ecor Pro’s four port DH3500/EPD200 and the EPD300 uses a separate air stream to dry its wheel, so it works at an equal pressure and air in the tent is not exchanged with the air in the room. The dehumidifier can be placed inside the tent and the ‘regen’ air to dry the wheel pumped into the tent and back out. Alternatively, the dehumidifier can be placed outside the tent and the air taken from the tent to the dehumidifier and back, which means the drying tent or chamber can be sealed around the ducts to give maximum efficiency.

Air recirculation 100%, air exchange 0%. That is efficient.

Moisture is "vented away".  No water is produced.  The moist air is vented to the outside or moved to another area that is vented. Most common installation.

Focussing the dry air gives faster drying times.  Example of "Positive Pressure" or forcing the dry air into areas it is needed

Recirculating the air to be dried gives a compound effect and gives faster drying.  This system is "Neutral Pressure" and is outside the room being dried.

Having the machine in the area being dried and recirculating the air is the most efficient way of drying.  This system is "Neutral Pressure" and is inside the room being dried.

Operating below zero and can operate in sealed rooms, 4-Hole allows even cold rooms and freezers to reduce moisture problems.

Gewicht 24.4 kg
Abmessungen 73 × 41 × 47 cm
(L x B x H)-(Gewicht)

24,82" x 13,86" x 13,58" - 45,19lbs

Technologie

Trockenmittel

Maximaler Auszug

45L-95pt

Leistung / Stecker / Kabellänge

1500W, 220V, 50Hz, 6,5A / Ja BS/EU

Strichcode

8720648456091.

Farbe / Material

Rostfreier Stahl

Kanal-Größen

80mm (3,0")-125mm (5")

Schwimmbad bereit

Nein

Humidistat Innen / Humidistat Option

Nein / Ja

Tragegriff/Wasserbehälter/Stromkabellänge

Ja / Nein / 5

Lüfterdrehzahlen/Schall

1 / 58dB

Temperatur öffnen

Minus 20?C bis plus 40?C

Neustart bei Stromausfall / Funktioniert vom DC-AC Coverter

Ja / Ja

Luftstrom m3/h

400 Prozess / 125 Absaugung

Neustart bei Stromausfall

Ja

Werke von DC-AC Coverter

Ja

Wassertank

Nein

Material

Stahlloser Stahl

Genehmigung

CE